Project: | Stanford Fullysampled 3D FSE Knees |
Anatomy: | Knee |
Fullysampled: | Yes |
Uploader: | mikgroup |
Tags: |
UUID | cc70c22f-1ddc-4a53-9503-e33d613de321 |
---|---|
Downloads | 3528 |
References | Epperson K, Sawyer AM, Lustig M, Alley M, Uecker M. Creation Of Fully Sampled MR Data Repository For Compressed Sensing Of The Knee. In: Proceedings of the 22nd Annual Meeting for Section for Magnetic Resonance Technologists, Salt Lake City, Utah, USA, 2013. |
Protocol Name | Sawyer_Knee_CompSensing_1 |
Series Description | Sawyer_Knee_CompSensing_1 |
System Vendor | GE MEDICAL SYSTEMS |
System Model | Orchestra SDK |
System Field Strength | 3.0 T |
Receiver Bandwidth | 50.0 |
Number of Channels | 8 |
Coil Name | C-GE_HDx TR Knee PA |
Institution Name | Lucas Center |
Station Name | No2 |
Matrix Size | 320 x 320 x 1 |
Field Of View | 160 mm x 160 mm x 153.6 mm |
Number of Slices | 256 |
Number of Phases | 1 |
Number of Contrasts | 1 |
Trajectory | cartesian |
Repetition Time | 1550 ms |
Echo Time | 25 ms |
Flip Angle | 90 ° |
Sequence Type | SE |
Upload Date | April 5, 2018, 9:19 p.m. |
Project: | Stanford Fullysampled 3D FSE Knees |
Anatomy: | Knee |
Fullysampled: | Yes |
Uploader: | mikgroup |
Tags: |
UUID | 280cf3f9-3b7e-4738-84e0-f72b21aa5266 |
---|---|
Downloads | 2708 |
References | Epperson K, Sawyer AM, Lustig M, Alley M, Uecker M. Creation Of Fully Sampled MR Data Repository For Compressed Sensing Of The Knee. In: Proceedings of the 22nd Annual Meeting for Section for Magnetic Resonance Technologists, Salt Lake City, Utah, USA, 2013. |
Protocol Name | Sawyer_Knee_CompSensing_1 |
Series Description | Sawyer_Knee_CompSensing_1 |
System Vendor | GE MEDICAL SYSTEMS |
System Model | Orchestra SDK |
System Field Strength | 3.0 T |
Receiver Bandwidth | 50.0 |
Number of Channels | 8 |
Coil Name | C-GE_HDx TR Knee PA |
Institution Name | Lucas Center |
Station Name | No2 |
Matrix Size | 320 x 320 x 1 |
Field Of View | 160 mm x 160 mm x 153.6 mm |
Number of Slices | 256 |
Number of Phases | 1 |
Number of Contrasts | 1 |
Trajectory | cartesian |
Repetition Time | 1550 ms |
Echo Time | 25 ms |
Flip Angle | 90 ° |
Sequence Type | SE |
Upload Date | April 5, 2018, 9:17 p.m. |
Project: | Stanford Fullysampled 3D FSE Knees |
Anatomy: | Knee |
Fullysampled: | Yes |
Uploader: | mikgroup |
Tags: |
UUID | 38b9a8e8-2779-4979-8602-5e8e5f902863 |
---|---|
Downloads | 2590 |
References | Epperson K, Sawyer AM, Lustig M, Alley M, Uecker M. Creation Of Fully Sampled MR Data Repository For Compressed Sensing Of The Knee. In: Proceedings of the 22nd Annual Meeting for Section for Magnetic Resonance Technologists, Salt Lake City, Utah, USA, 2013. |
Protocol Name | Sawyer_Knee_CompSensing_1 |
Series Description | Sawyer_Knee_CompSensing_1 |
System Vendor | GE MEDICAL SYSTEMS |
System Model | Orchestra SDK |
System Field Strength | 3.0 T |
Receiver Bandwidth | 50.0 |
Number of Channels | 8 |
Coil Name | C-GE_HDx TR Knee PA |
Institution Name | Lucas Center |
Station Name | No2 |
Matrix Size | 320 x 320 x 1 |
Field Of View | 160 mm x 160 mm x 153.6 mm |
Number of Slices | 256 |
Number of Phases | 1 |
Number of Contrasts | 1 |
Trajectory | cartesian |
Repetition Time | 1550 ms |
Echo Time | 25 ms |
Flip Angle | 90 ° |
Sequence Type | SE |
Upload Date | April 5, 2018, 8:21 p.m. |
Project: | Stanford Fullysampled 3D FSE Knees |
Anatomy: | Knee |
Fullysampled: | Yes |
Uploader: | mikgroup |
Tags: |
UUID | 54c077b2-7d68-4e77-b729-16afbccae9ac |
---|---|
Downloads | 3708 |
References | Epperson K, Sawyer AM, Lustig M, Alley M, Uecker M. Creation Of Fully Sampled MR Data Repository For Compressed Sensing Of The Knee. In: Proceedings of the 22nd Annual Meeting for Section for Magnetic Resonance Technologists, Salt Lake City, Utah, USA, 2013. |
Protocol Name | Sawyer_Knee_CompSensing_1 |
Series Description | Sawyer_Knee_CompSensing_1 |
System Vendor | GE MEDICAL SYSTEMS |
System Model | Orchestra SDK |
System Field Strength | 3.0 T |
Receiver Bandwidth | 50.0 |
Number of Channels | 8 |
Coil Name | C-GE_HDx TR Knee PA |
Institution Name | Lucas Center |
Station Name | No2 |
Matrix Size | 320 x 320 x 1 |
Field Of View | 160 mm x 160 mm x 153.6 mm |
Number of Slices | 256 |
Number of Phases | 1 |
Number of Contrasts | 1 |
Trajectory | cartesian |
Repetition Time | 1550 ms |
Echo Time | 25 ms |
Flip Angle | 90 ° |
Sequence Type | SE |
Upload Date | April 5, 2018, 8:19 p.m. |
Project: | Stanford Fullysampled 3D FSE Knees |
Anatomy: | Knee |
Fullysampled: | Yes |
Uploader: | mikgroup |
Tags: |
UUID | ec00945c-ad90-46b7-8c38-a69e9e801074 |
---|---|
Downloads | 2706 |
References | Epperson K, Sawyer AM, Lustig M, Alley M, Uecker M. Creation Of Fully Sampled MR Data Repository For Compressed Sensing Of The Knee. In: Proceedings of the 22nd Annual Meeting for Section for Magnetic Resonance Technologists, Salt Lake City, Utah, USA, 2013. |
Protocol Name | Sawyer_Knee_CompSensing_1 |
Series Description | Sawyer_Knee_CompSensing_1 |
System Vendor | GE MEDICAL SYSTEMS |
System Model | Orchestra SDK |
System Field Strength | 3.0 T |
Receiver Bandwidth | 50.0 |
Number of Channels | 8 |
Coil Name | C-GE_HDx TR Knee PA |
Institution Name | Lucas Center |
Station Name | No2 |
Matrix Size | 320 x 320 x 1 |
Field Of View | 160 mm x 160 mm x 153.6 mm |
Number of Slices | 256 |
Number of Phases | 1 |
Number of Contrasts | 1 |
Trajectory | cartesian |
Repetition Time | 1550 ms |
Echo Time | 25 ms |
Flip Angle | 90 ° |
Sequence Type | SE |
Upload Date | April 5, 2018, 8:15 p.m. |
Project: | Stanford Fullysampled 3D FSE Knees |
Anatomy: | Knee |
Fullysampled: | Yes |
Uploader: | mikgroup |
Tags: |
UUID | dd969854-ec56-4ccc-b7ac-ff4cd7735095 |
---|---|
Downloads | 2597 |
References | Epperson K, Sawyer AM, Lustig M, Alley M, Uecker M. Creation Of Fully Sampled MR Data Repository For Compressed Sensing Of The Knee. In: Proceedings of the 22nd Annual Meeting for Section for Magnetic Resonance Technologists, Salt Lake City, Utah, USA, 2013. |
Protocol Name | Sawyer_Knee_CompSensing_1 |
Series Description | Sawyer_Knee_CompSensing_1 |
System Vendor | GE MEDICAL SYSTEMS |
System Model | Orchestra SDK |
System Field Strength | 3.0 T |
Receiver Bandwidth | 50.0 |
Number of Channels | 8 |
Coil Name | C-GE_HDx TR Knee PA |
Institution Name | Lucas Center |
Station Name | No2 |
Matrix Size | 320 x 320 x 1 |
Field Of View | 160 mm x 160 mm x 153.6 mm |
Number of Slices | 256 |
Number of Phases | 1 |
Number of Contrasts | 1 |
Trajectory | cartesian |
Repetition Time | 1550 ms |
Echo Time | 25 ms |
Flip Angle | 90 ° |
Sequence Type | SE |
Upload Date | April 5, 2018, 8:05 p.m. |
Project: | Stanford Fullysampled 3D FSE Knees |
Anatomy: | Knee |
Fullysampled: | Yes |
Uploader: | mikgroup |
Tags: |
UUID | efa383b6-9446-438a-9901-1fe951653dbd |
---|---|
Downloads | 2670 |
References | Epperson K, Sawyer AM, Lustig M, Alley M, Uecker M. Creation Of Fully Sampled MR Data Repository For Compressed Sensing Of The Knee. In: Proceedings of the 22nd Annual Meeting for Section for Magnetic Resonance Technologists, Salt Lake City, Utah, USA, 2013. |
Protocol Name | Sawyer_Knee_CompSensing_1 |
Series Description | Sawyer_Knee_CompSensing_1 |
System Vendor | GE MEDICAL SYSTEMS |
System Model | Orchestra SDK |
System Field Strength | 3.0 T |
Receiver Bandwidth | 50.0 |
Number of Channels | 8 |
Coil Name | C-GE_HDx TR Knee PA |
Institution Name | Lucas Center |
Station Name | No2 |
Matrix Size | 320 x 320 x 1 |
Field Of View | 160 mm x 160 mm x 153.6 mm |
Number of Slices | 256 |
Number of Phases | 1 |
Number of Contrasts | 1 |
Trajectory | cartesian |
Repetition Time | 1550 ms |
Echo Time | 25 ms |
Flip Angle | 90 ° |
Sequence Type | SE |
Upload Date | April 5, 2018, 7:46 p.m. |
Project: | Stanford Fullysampled 3D FSE Knees |
Anatomy: | Knee |
Fullysampled: | Yes |
Uploader: | mikgroup |
Tags: |
UUID | 8eff1229-8074-41fa-8b5e-441b501f10e3 |
---|---|
Downloads | 1649 |
References | Epperson K, Sawyer AM, Lustig M, Alley M, Uecker M. Creation Of Fully Sampled MR Data Repository For Compressed Sensing Of The Knee. In: Proceedings of the 22nd Annual Meeting for Section for Magnetic Resonance Technologists, Salt Lake City, Utah, USA, 2013. |
Protocol Name | Sawyer_Knee_CompSensing_1 |
Series Description | Sawyer_Knee_CompSensing_1 |
System Vendor | GE MEDICAL SYSTEMS |
System Model | Orchestra SDK |
System Field Strength | 3.0 T |
Receiver Bandwidth | 50.0 |
Number of Channels | 8 |
Coil Name | C-GE_HDx TR Knee PA |
Institution Name | Lucas Center |
Station Name | No2 |
Matrix Size | 320 x 320 x 1 |
Field Of View | 160 mm x 160 mm x 153.6 mm |
Number of Slices | 256 |
Number of Phases | 1 |
Number of Contrasts | 1 |
Trajectory | cartesian |
Repetition Time | 1550 ms |
Echo Time | 25 ms |
Flip Angle | 90 ° |
Sequence Type | SE |
Upload Date | April 5, 2018, 7:27 p.m. |
Project: | Stanford Fullysampled 3D FSE Knees |
Anatomy: | Knee |
Fullysampled: | Yes |
Uploader: | mikgroup |
Tags: |
UUID | 7a9f028c-8667-48aa-8e08-0acf3320c8d4 |
---|---|
Downloads | 1637 |
References | Epperson K, Sawyer AM, Lustig M, Alley M, Uecker M. Creation Of Fully Sampled MR Data Repository For Compressed Sensing Of The Knee. In: Proceedings of the 22nd Annual Meeting for Section for Magnetic Resonance Technologists, Salt Lake City, Utah, USA, 2013. |
Protocol Name | Sawyer_Knee_CompSensing_1 |
Series Description | Sawyer_Knee_CompSensing_1 |
System Vendor | GE MEDICAL SYSTEMS |
System Model | Orchestra SDK |
System Field Strength | 3.0 T |
Receiver Bandwidth | 50.0 |
Number of Channels | 8 |
Coil Name | C-GE_HDx TR Knee PA |
Institution Name | Lucas Center |
Station Name | No2 |
Matrix Size | 320 x 320 x 1 |
Field Of View | 160 mm x 160 mm x 153.6 mm |
Number of Slices | 256 |
Number of Phases | 1 |
Number of Contrasts | 1 |
Trajectory | cartesian |
Repetition Time | 1550 ms |
Echo Time | 25 ms |
Flip Angle | 90 ° |
Sequence Type | SE |
Upload Date | April 5, 2018, 5:26 p.m. |
Project: | Stanford Fullysampled 3D FSE Knees |
Anatomy: | Knee |
Fullysampled: | Yes |
Uploader: | mikgroup |
Tags: |
UUID | ee2efe48-1e9d-480e-9364-e53db01532d4 |
---|---|
Downloads | 1757 |
References | Epperson K, Sawyer AM, Lustig M, Alley M, Uecker M. Creation Of Fully Sampled MR Data Repository For Compressed Sensing Of The Knee. In: Proceedings of the 22nd Annual Meeting for Section for Magnetic Resonance Technologists, Salt Lake City, Utah, USA, 2013. |
Protocol Name | Sawyer_Knee_CompSensing_1 |
Series Description | Sawyer_Knee_CompSensing_1 |
System Vendor | GE MEDICAL SYSTEMS |
System Model | Orchestra SDK |
System Field Strength | 3.0 T |
Receiver Bandwidth | 50.0 |
Number of Channels | 8 |
Coil Name | C-GE_HDx TR Knee PA |
Institution Name | Lucas Center |
Station Name | No2 |
Matrix Size | 320 x 320 x 1 |
Field Of View | 160 mm x 160 mm x 153.6 mm |
Number of Slices | 256 |
Number of Phases | 1 |
Number of Contrasts | 1 |
Trajectory | cartesian |
Repetition Time | 1550 ms |
Echo Time | 25 ms |
Flip Angle | 90 ° |
Sequence Type | SE |
Upload Date | April 5, 2018, 5:12 p.m. |